Siemens Simatic AX Motion Control Engineering: Text-Based Motion, PLCopen and Git for Software-Defined Automation

Siemens Simatic AX Motion Control Engineering: Text-Based Motion, PLCopen and Git for Software-Defined Automation

Simatic AX Motion Control Engineering: Text-Based Motion, PLCopen and Git

For two decades, the hardest part of putting a Siemens motion project under version control was never the motion code. PLCopen-style calls such as MC_Power and MC_MoveAbsolute were always just text. The problem was the axis itself: the technology object with its scaling, limits, encoder settings and drive telegram, locked inside a binary TIA Portal project that Git could store but never meaningfully diff. On 17 November 2026, Siemens announced Simatic AX Motion Control Engineering (MCE), which moves that axis configuration into the same text-based, VS Code-based environment as the PLC logic. That matters now because machine builders are hiring software engineers who expect pull requests, CI and code review for everything that ships. This post explains what MCE actually is, where it sits in the Simatic AX toolchain, how it compares with TIA Portal, TwinCAT and CODESYS, and what a motion-aware CI pipeline should look like.

What this covers: the news and its verified facts, the Simatic AX architecture, the technology-object-as-code shift, a pipeline example, a vendor comparison, failure modes and a practical adoption checklist.

Context and Background

Siemens has been building Simatic AX as a parallel engineering track to TIA Portal for several years. TIA Portal remains the integrated, graphical, all-in-one environment most Siemens users know. Simatic AX takes the opposite design stance: a lean, Visual Studio Code-based IDE, a command-line-first toolchain, plain-text project files, a package manager called apax, and an object-oriented dialect of IEC 61131-3 Structured Text (ST). Siemens’ own developer overview describes AX as built on VS Code and originally released in an Early Access model for selected productive use cases.

The November 2026 press release from Erlangen contains three distinct pieces of news. First, Simatic AX Logic Control Engineering (LCE), which had previously been released in the US market, is now generally available worldwide. Second, LCE has supported ladder programming through a graphical editor called XLad, and the Simatic S7-1200 G2 controller, since June 2026. Third, and new, Simatic AX Motion Control Engineering adds motion control to the same text-based environment, with technology objects configured “in an IT-oriented, document-based way,” PLCopen support and direct Git integration. Siemens said MCE would be shown publicly for the first time at the SPS trade fair in Nuremberg, and that both LCE and MCE are available through the Siemens Digital Exchange marketplace.

The incumbents frame the stakes. In TIA Portal, an S7-1500 axis is a technology object (TO) edited through graphical configuration screens and commanded with PLCopen-derived instructions. Beckhoff’s TwinCAT has long configured NC axes in a Visual Studio-hosted XAE environment and now pushes TwinCAT MC3 and the plain-text TwinCAT PLC++. CODESYS SoftMotion configures axes as device-tree objects and commands them with the SM3_Basic library. If you want the background on the function blocks themselves, our explainer on PLCopen motion control function blocks and the axis state machine covers MC_Power, MC_Home and the state diagram in depth. The Siemens press release is the primary source for the launch facts used here.

The thesis of this post is simple. PLCopen standardised the verbs of motion a long time ago. What Simatic AX motion control engineering changes is the noun: the axis definition becomes a reviewable, diffable, templatable text artifact. That is the piece that finally lets motion participate in a real software delivery pipeline.

How Simatic AX Motion Control Engineering Fits the AX Architecture

Simatic AX Motion Control Engineering is Siemens’ extension of the Simatic AX IDE that lets engineers configure S7-1500 motion technology objects as plain-text documents and program them in Structured Text with PLCopen-style instructions, all inside one VS Code-based workspace under Git, without switching to TIA Portal for the motion part of a project.

Simatic AX motion control engineering reference architecture from Git repository to S7-1500 technology objects and drives

Figure 1: Reference architecture of a Simatic AX project with motion. Source, hardware configuration and technology-object documents live in one Git repository and flow through the apax toolchain to an S7-1500 CPU.

Figure 1 shows the layers. At the top is a single Git repository. It holds ST source for the application logic, textual hardware configuration for the CPU and I/O, and — new with MCE — textual documents describing each axis technology object. The apax package manager pulls in the SDK, catalogs and libraries. Command-line tools compile the software and the hardware configuration and load both into the controller. On the CPU, the motion runtime executes the technology objects in the motion control servo cycle, and they talk to drives over the fieldbus.

The toolchain is CLI-first, and that is the real enabler

It is easy to treat “text-based” as cosmetic. It is not. The enabling property of Simatic AX is that every step a human performs in the IDE has a command-line equivalent, so a CI runner can perform it too. Siemens’ public application example for AX hardware engineering on GitHub makes this concrete. Its apax.yml defines scripts that install GSDML device descriptions (hwc install-gsd), generate configuration templates for named modules such as an S7-1500 CPU 1516-3 PN/DP and ET 200SP I/O modules, compile the hardware configuration (hwc compile), load it (hwld load), load software (sld load), switch the CPU between RUN and STOP (plc-info set-mode), read the diagnostic buffer, and compare online and offline hardware (hw-diag compare).

That example targets "1500" and depends on @ax/sdk and an @ax/simatic-ax catalog at version ^2510.0.0. A newer Siemens library template references @ax-as/s7-sdk and an @ax-as/s7-catalog at ^2610.0.0. The version numbers look like calendar versions — 2510 and 2610 — which suggests a release cadence tied to year and month. Siemens has not, in the sources reviewed here, published an explicit statement of that convention, so treat it as an inference.

The point for motion is that the same pipeline that compiles and loads logic and hardware can now, in principle, compile and load technology objects. A motion change becomes a commit, not a sequence of mouse clicks in a configuration dialog.

The technology object becomes a document

In TIA Portal, a TO is a structured data block plus configuration metadata, edited through a parameter tree: drive and encoder connection, mechanics and leadscrew pitch, modulo settings, dynamic limits for velocity, acceleration and jerk, homing mode, position monitoring and following-error tolerance, and control-loop gains. The S7-1500 motion functions documented for TIA Portal V21 include speed axes, positioning axes, synchronous axes and external encoders, plus measuring input, output cam and, on S7-1500T CPUs, kinematics and interpreter functions.

MCE’s product page, at the time of writing, states that it supports textual configuration of technology objects for speed, positioning and gear-synchronous axes, on the S7-1500 only. It also lists templating support, language-server features in the editor, and a dedicated Axis Control and Status Panel for commissioning and tuning. Notice what is not listed: cams, output cams, measuring inputs and kinematics. Whether those arrive later is not stated. If your machine depends on electronic cams or robot kinematics, plan as though they are not yet covered by MCE until Siemens documents otherwise.

Why is a document-shaped TO such a big deal? Because the dangerous changes in motion projects are usually parameter changes, not code changes. A wrong gear ratio, a doubled acceleration limit or a software limit switch moved by 50 millimetres will pass compilation and will happily move a real axis. In a binary project, a reviewer sees “project changed.” In a text document, a reviewer sees the exact line where maxAcceleration went from one value to another — and can block the merge. Templating amplifies this: ten identical conveyor axes derived from one template means one reviewed definition instead of ten hand-edited dialogs drifting apart.

PLCopen is the stable interface between code and axis

MCE’s press material names PLCopen support explicitly. PLCopen’s Motion Control specification defines function blocks and an axis state machine — Disabled, Standstill, Homing, Discrete Motion, Continuous Motion, Synchronized Motion, Stopping and ErrorStop — so that application code expresses intent the same way across vendors. Siemens’ S7-1500 motion instructions have long been modelled on that specification.

Layered view of PLCopen function blocks between object-oriented Structured Text and S7-1500 technology objects

Figure 2: Layering in a text-based motion project. Object-oriented application classes call a reusable axis-control block, which issues PLCopen-style instructions against a technology object that the motion runtime executes.

Figure 2 shows why this layering is useful in an object-oriented ST environment. Siemens’ community organisation on GitHub publishes LAxisCtrl, an AX library whose AxisControl block is described as PLCopen-compliant and which wraps enabling, homing, jogging, absolute and relative positioning, superimposed motion, gearing, camming and diagnostics for S7-1500 TOs. It ships in four packages split by Motion Control version (v9 or v10) and feature set: the Technology variants for S7-1500T, and Standard variants for S7-1500 that omit gearing, camming, phasing and offset. Another public example shows object-oriented motion classes in AX wrapped into a function block, because TIA Portal cannot consume AX’s object-oriented constructs directly; the wrapper is exported to TIA as a global library with apax create-tialib.

This tells you how Siemens expects teams to structure motion code. Application logic lives in classes. A thin, tested axis-control layer translates intent into PLCopen calls. The TO absorbs drive-specific detail. Each layer has a separate change rhythm and a separate reviewer, which is exactly what a Git workflow is good at.

Walk-through: A CI Pipeline for Simatic AX Motion Control Engineering

The rest of this section walks through what a team can build once motion is text — the practical payoff of Simatic AX motion control engineering. Two caveats up front. Siemens has not, in public documentation reviewed for this post, published the file schema for MCE technology-object documents. And the exact AX type names for S7-1500 TOs depend on library versions. So every code and configuration listing below is illustrative: it shows the shape of a workflow, not copy-paste syntax.

Step 1: Structure the repository around change rhythm

A practical layout separates the things that change at different speeds and need different reviewers:

machine-line-7/
  apax.yml                 # package manifest, scripts, targets
  apax-lock.json           # pinned dependency versions
  hwc/                     # textual hardware configuration + GSDML
  motion/                  # technology-object documents (MCE)
    templates/conveyor-axis.template
    axes/infeed-1.axis
    axes/infeed-2.axis
    axes/cutter.axis
  src/                     # Structured Text application
    machine/
    motion/AxisFacade.st
  test/                    # AxUnit tests
  .github/workflows/ci.yml
  CODEOWNERS               # motion/ owned by the controls lead

The CODEOWNERS line is the single most important governance control in a motion repository. It routes every change under motion/ to someone who understands mechanics and safety distances, while ordinary logic changes go through normal software review. Git hosting platforms enforce this mechanically, which is far stronger than a checklist pinned next to the engineering station.

Step 2: Keep the PLCopen call surface thin and testable

The application should not scatter motion instructions everywhere. Wrap them in one facade per axis role. The listing below is illustrative ST in the object-oriented AX style. Parameter names follow the S7-1500 PLCopen-style instructions as documented for TIA Portal; the AX library types may differ.

NAMESPACE Line7.Motion
    CLASS PUBLIC AxisFacade
        VAR PRIVATE
            _power  : MC_POWER;
            _home   : MC_HOME;
            _moveAbs: MC_MOVEABSOLUTE;
        END_VAR

        METHOD PUBLIC Enable : BOOL
            VAR_IN_OUT axis : TO_PositioningAxis; END_VAR
            _power(Axis := axis, Enable := TRUE, StartMode := 1, StopMode := 0);
            Enable := _power.Status;
        END_METHOD

        METHOD PUBLIC MoveTo : BOOL
            VAR_IN_OUT axis : TO_PositioningAxis; END_VAR
            VAR_INPUT
                execute  : BOOL;
                position : LREAL;
                velocity : LREAL;
            END_VAR
            // Guard: never command beyond the reviewed process window
            IF position < 0.0 OR position > 1200.0 THEN
                MoveTo := FALSE;
                RETURN;
            END_IF;
            _moveAbs(Axis := axis, Execute := execute, Position := position,
                     Velocity := velocity);
            MoveTo := _moveAbs.Done;
        END_METHOD
    END_CLASS
END_NAMESPACE

The guard clause matters more than it looks. TO software limits are the hard stop. An application-level process window, checked before the instruction is even issued, gives a second, testable barrier that lives in code review. Note that neither is a substitute for a certified safety function such as Safely-Limited Position in the drive; more on that later.

Step 3: Unit-test the logic, not the physics

Simatic AX ships a unit-test framework, AxUnit, included with the SDK. Tests are classes marked {TestFixture}, test methods are marked {Test}, and assertions such as Equal, NotEqual and InRange come from AxUnit.Assert. Tests run with apax test, according to Siemens’ learning material and community guides. A sensible split is to unit-test the decision logic — sequencing, interlocks, the process-window guard above, recipe-to-setpoint conversion — with the TO replaced by a mock. Siemens’ community organisation publishes a mocks repository aimed at exactly this pattern.

What unit tests cannot validate is dynamics. Whether a 4 m/s² ramp causes a 30 kg carriage to overshoot depends on the drive tuning and mechanics, and no host-side test will tell you. That belongs in a simulation stage or on a test rig.

Step 4: Wire it into CI

Sequence of a Simatic AX motion CI pipeline from commit through build, test, simulation and gated load

Figure 3: A gated pipeline for motion changes. Logic is tested automatically; technology-object changes trigger an extra simulation stage and a human approval before anything reaches a real controller.

Figure 3 shows the sequence. The listing below is an illustrative GitHub Actions workflow, not a Siemens-published template. It assumes an apax registry token stored as a secret and a self-hosted runner on the plant network for the load stage.

name: line7-ci
on:
  pull_request:
  push:
    branches: [main]

jobs:
  build-test:
    runs-on: ubuntu-latest
    outputs:
      changed: ${{ steps.motion.outputs.changed }}
    steps:
      - uses: actions/checkout@v4
      - name: Install apax dependencies
        run: |
          apax login --registry "$AX_REGISTRY_URL" --password "$AX_TOKEN"   # placeholder flags
          apax install --immutable
        env:
          AX_TOKEN: ${{ secrets.AX_TOKEN }}
          AX_REGISTRY_URL: ${{ vars.AX_REGISTRY_URL }}
      - name: Build software
        run: apax build
      - name: Unit tests with coverage
        run: apax test -c
      - name: Compile hardware configuration
        run: apax hw_compile
      - name: Detect motion changes
        id: motion
        run: |
          git diff --name-only origin/main... | grep '^motion/' && echo "changed=true" >> "$GITHUB_OUTPUT" || true

  simulate:
    needs: build-test
    if: needs.build-test.outputs.changed == 'true'
    runs-on: [self-hosted, plcsim]
    steps:
      - run: apax compile_and_load_all   # to a simulated S7-1500, not a machine
      - run: ./scripts/run-motion-scenarios.sh

  deploy:
    needs: [build-test]
    if: github.ref == 'refs/heads/main'
    environment: line7-commissioning      # requires manual approval
    runs-on: [self-hosted, plant-net]
    steps:
      - run: apax compile_and_load_all

Three design decisions are worth calling out. The --immutable install (or your equivalent) pins dependencies from the lock file, so a CI build cannot silently pick up a new motion library minor version. The motion-change detector turns an expensive simulation stage on only when axis documents change, which keeps ordinary logic PRs fast. And the deploy job uses a protected environment, so a human with commissioning authority approves every load. A pipeline that can push motion parameters to a live machine unattended is a hazard, not a convenience.

The script names hw_compile and compile_and_load_all mirror the Siemens hardware-engineering example; the registry variable and login flags shown are placeholders you must replace with what your Siemens subscription documents.

Step 5: Make the motion diff reviewable

Text is only reviewable if diffs are small and meaningful. Three habits help. Keep one TO per file, so a diff names the axis. Derive repeated axes from templates and override only what differs, so a diff shows the deviation from the standard rather than 200 duplicated lines. And add a CI step that extracts the safety-relevant parameters — software limits, maximum velocity, acceleration, jerk and following-error tolerance — into a summary comment on the pull request. Reviewers then see “cutter: max velocity 800 → 1,200 mm/s” in plain language, rather than hunting through a document.

Capacity and cost: what changes for the team

The economics are easier to reason about than the technology. Simatic AX LCE is sold as a subscription; Siemens’ product page refers to a yearly subscription with an initial three-month trial, but publishes no price. MCE’s pricing is not public either, and neither is the list of supported drives beyond the generic S7-1500 motion stack. So any cost comparison with a perpetual TIA Portal licence must be built from your own Siemens quote.

The engineering cost model is clearer. The expensive event in motion work is a wrong parameter discovered on the machine — a crash, a broken tool, or a day of recommissioning. If text-based review and automated checks catch even one such error per project, they plausibly pay for the pipeline work. That is an argument, not a measured figure; no public study quantifying it for MCE exists yet.

Simatic AX Motion Control Engineering vs TIA Portal, TwinCAT and CODESYS SoftMotion

No serious buyer evaluates MCE in isolation. The realistic alternatives are staying on TIA Portal technology objects, or a PC-based stack such as Beckhoff TwinCAT or CODESYS SoftMotion. The matrix below compares them on the dimensions that matter for a software-defined workflow. Entries are drawn from vendor documentation cited in this post; “not public” means the vendor has not published the detail, not that it is absent.

Dimension Simatic AX MCE TIA Portal TOs Beckhoff TwinCAT (NC2 / MC3) CODESYS SoftMotion
Editor VS Code-based AX IDE TIA Portal (Windows desktop) TwinCAT XAE in Visual Studio shell CODESYS Development System
Axis definition Text documents, templatable Graphical TO configuration in binary project Axis objects in project tree; XML-based project files Axis objects in device tree; project file
Motion programming Object-oriented ST, PLCopen-style SCL/LAD/FBD with PLCopen-derived instructions Tc2_MC2 (NC) or Tc3_Mc3 (MC3), PLCopen-compliant SM3_Basic, PLCopen-based
Axis types at launch Speed, positioning, gear-synchronous Speed, positioning, synchronous, external encoder; cams and kinematics on T-CPUs Broad, incl. camming in MC3 Broad, incl. cams and CNC/robotics add-ons
Git friendliness Native; plain text by design Needs export or version-control add-ons Workable with XML; PLC++ moves code to plain text Workable with add-ons; binary project by default
CLI / headless build Yes, CLI-first toolchain Via TIA Openness API (Windows) Automation Interface; PLC++ stand-alone compiler Scripting and automation APIs
Target hardware S7-1500 only S7-1200, S7-1500, S7-1500T, others Beckhoff IPCs Many vendors’ CODESYS runtimes
Licensing model Subscription (price not public) Licences per TIA edition and options Per-function runtime licences (TFxxxx) Per-axis-count SoftMotion licences

Reading the matrix

The first thing the table shows is that Simatic AX motion control engineering is not trying to win on breadth. TIA Portal’s motion stack is older and covers more object types, and PC-based platforms ship cams, kinematics and CNC options. MCE wins on a narrower axis: it is the only option here where the axis definition was designed as text from the start, rather than retrofitted.

The second point concerns TwinCAT. Beckhoff’s TwinCAT MC3 is positioned as the successor to NC2, with multi-core and multi-task execution and PLCopen-compliant blocks in the Tc3_Mc3 library. Beckhoff also offers TwinCAT PLC++, which stores program code in plain text at file level and includes a stand-alone command-line compiler; Beckhoff claims up to 1.5 times faster execution of the same code, and up to a factor of three with further optimisation. Those are vendor claims. Taken together, PLC++ and MC3 are Beckhoff’s own answer to the same pressure, so “text-based motion” is becoming an industry direction rather than a Siemens differentiator. Our CODESYS vs TwinCAT soft PLC comparison goes deeper on the runtime side.

The third point is about CODESYS. SoftMotion’s strength is hardware breadth: the same SM3_Basic code can run on runtimes from many vendors, with licences sold by axis count. Its version-control story depends on add-ons and project-file handling, which is workable but less native than a text-first design.

When to choose which

Choose Simatic AX motion control engineering when you are already committed to S7-1500, your machine uses speed, positioning and gearing axes, and your team wants motion inside a Git-and-CI workflow. Machine builders migrating from SIMOTION are a natural fit; Siemens names Contiweb, which it says is migrating machines from SIMOTION to S7-1500, as an AX reference customer.

Stay on TIA Portal technology objects when the project needs cams, output cams, measuring inputs or kinematics today, when maintenance technicians must open the project in the tool they know, or when Safety Integrated and drive commissioning live in one integrated project you do not want to split.

Choose a PC-based platform when hardware independence or very high axis counts drive the architecture, or when you are building a software-defined manufacturing stack around virtual PLCs and containers. That is the broader trend of which MCE is one vendor’s expression.

Migration: Moving an Existing S7-1500 Motion Project

Most teams evaluating Simatic AX motion control engineering already have TIA Portal motion projects. A big-bang rewrite is rarely wise, and the AX toolchain itself suggests a gentler path.

Start with the logic, not the axes. AX can export object-oriented code to TIA Portal as a global library, wrapped in a function block, as Siemens’ motion application example shows. That lets a team write and unit-test new axis-control logic in AX while the production project, including its TOs, stays in TIA Portal. Nothing on the machine changes except a library version.

Next, freeze and document the existing TO parameters. Before moving any axis into MCE documents, export or transcribe the current configuration and treat it as the golden baseline. The first MCE version of each axis should reproduce that baseline exactly, and the review should confirm parity line by line. Only after parity is proven should anyone “clean up” the parameters.

Then migrate one machine module at a time, choosing the simplest axes first. A speed-controlled conveyor is a good pilot. A gear-synchronous axis following a master is a reasonable second step. Anything that depends on cams waits for documented MCE support.

Finally, recognise the people cost. A maintenance technician who can open a TIA project on a field laptop may not be comfortable in a VS Code workspace with a terminal. Siemens’ Axis Control and Status Panel is aimed at commissioning and tuning, but your service organisation still needs training, a defined toolchain image and a way to get the exact Git revision that runs on the machine. For the version-control mechanics across vendors, see our guide to Git and CI/CD for PLC projects in TIA Portal, Simatic AX, CODESYS, TwinCAT and Studio 5000.

Trade-offs, Gotchas, and What Goes Wrong

Simatic AX motion control engineering removes one class of problems and introduces others. The failure modes below are the ones most likely to bite teams in their first year.

Decision flow for gating Simatic AX motion changes by risk before loading to a machine

Figure 4: A risk-based gate for motion changes. The path a change takes depends on whether it touches logic only, non-safety TO parameters, or dynamics and limits.

Merge conflicts in parameters are semantic, not textual. Two branches can each change a different line of an axis document and merge cleanly, while the combination is unsafe. For example, one branch raises maximum velocity and another shortens the software limit. Git sees no conflict. Figure 4’s gate exists because a clean merge proves nothing about physics. Re-run the simulation stage on the merged result, not just on each branch.

Templates spread mistakes as efficiently as they spread fixes. If ten axes inherit one template, a bad value in that template moves ten axes. Require that template changes list every derived axis in the pull request description, and treat a template edit as a change to every one of them.

Drift between repository and controller. The value of Git collapses if someone tunes gains online with the Axis Control and Status Panel and never commits the result. The hardware-engineering example’s hw-diag compare and sld compare scripts point to the remedy: run an online-versus-offline comparison as a scheduled job and alert on drift. Make “tuned values must be committed before the shift ends” an explicit rule.

Scope gaps at launch. The product page lists speed, positioning and gear-synchronous axes on the S7-1500. Cams, kinematics and S7-1200 G2 motion are not listed for MCE. A project that half-lives in MCE and half in TIA Portal loses most of the single-source-of-truth benefit.

Safety is not a pipeline stage. Nothing about Git, CI or PLCopen makes a motion system functionally safe. Safe torque off, safely limited speed and safely limited position belong in certified drive or fail-safe CPU functions, validated under IEC 61508-derived processes. A green pipeline is evidence of software hygiene, not of safety integrity.

Toolchain supply chain. apax packages come from registries, and a build depends on network access and credentials. Pin versions with lock files, verify package signatures where the registry supports them, and keep an offline mirror for plants without internet access. A machine you cannot rebuild in ten years is a liability.

Subscription dependency. A yearly subscription model means engineering access is tied to licence status. Clarify with Siemens what happens to existing projects, loads and diagnostics if a subscription lapses, before you put a production line on it.

Practical Recommendations

Treat Simatic AX motion control engineering as a pilot, not a platform migration, for the first project. The technology is new and its documented scope is narrow, but the workflow it enables is the right direction. Pick a machine module with simple axes and a team that already works in Git. Measure two things: how many parameter errors review and CI catch before commissioning, and how long commissioning takes compared with a similar TIA-based module.

Invest early in the governance layer, because it outlives any tool. Code owners for motion files, a protected deployment environment, a parameter-summary bot on pull requests and a drift check against the live controller will serve you whether motion lives in MCE, TIA Portal or TwinCAT. Keep the PLCopen call surface thin and wrapped, so a future change of platform touches one layer. Our post on PLC scan cycles and IEC 61131-3 task scheduling covers how motion calls interact with cyclic tasks, which matters when you restructure code into classes.

Finally, verify what is not public before you commit. Ask Siemens for the supported drive list, the MCE technology-object schema, the roadmap for cams and kinematics, the licence terms and offline-build options.

A short checklist for the pilot:

  • Confirm the CPU is an S7-1500 and the axes are speed, positioning or gear-synchronous.
  • Put motion/ under code owners with a controls lead as required reviewer.
  • Pin apax dependencies with a lock file and mirror the registry.
  • Wrap PLCopen calls in one tested facade per axis role.
  • Gate TO changes behind simulation and a protected, manual load stage.
  • Schedule online-versus-offline comparisons and alert on drift.
  • Keep safety functions in certified drive or F-CPU logic, outside the pipeline’s authority.

Frequently Asked Questions

What is Simatic AX Motion Control Engineering?

Simatic AX Motion Control Engineering is a Siemens product, announced on 17 November 2026, that adds motion control to the text-based Simatic AX environment. Engineers configure S7-1500 technology objects as documents rather than in graphical dialogs, program motion in Structured Text with PLCopen support, and version everything in Git. It sits alongside Simatic AX Logic Control Engineering, so logic and motion share one VS Code-based workspace and one command-line toolchain. Siemens distributes both through the Siemens Digital Exchange marketplace, and first showed MCE publicly at the SPS fair in Nuremberg.

Does Simatic AX replace TIA Portal?

No, not on the evidence available. Siemens positions Simatic AX as an engineering environment for IT-skilled engineers and software-defined automation, while TIA Portal remains its integrated graphical tool with much broader device and function coverage. AX can even export object-oriented code to TIA Portal as a global library. In practice, many teams will run both for years: AX for code-heavy modules and CI-driven projects, TIA Portal for safety, drives commissioning and functions MCE does not yet cover, such as cams and kinematics.

Which controllers and axis types does MCE support?

Siemens’ product page says MCE supports the SIMATIC S7-1500 only, with textual configuration of technology objects for speed axes, positioning axes and gear-synchronous axes. Simatic AX Logic Control Engineering supports both S7-1500 and S7-1200 G2, but motion on S7-1200 G2 is not listed for MCE. The page does not list cams, output cams, measuring inputs or kinematics. Siemens has not published a supported-drive list in the sources reviewed, so confirm drive compatibility directly with Siemens before planning a project.

Is Simatic AX motion programming PLCopen compliant?

Siemens states that MCE supports PLCopen, and its S7-1500 motion instructions have long been modelled on the PLCopen Motion Control function blocks, such as MC_Power, MC_Home and MC_MoveAbsolute. Siemens’ public LAxisCtrl library for AX describes its AxisControl block as PLCopen-compliant. However, no PLCopen certification statement specific to MCE was found when this post was written. Treat “PLCopen support” as functional alignment with the standard’s blocks and state machine, not as a certified conformance claim.

How much does Simatic AX cost?

Siemens has not published prices. The Logic Control Engineering product page refers to a yearly subscription with an initial three-month trial, and both LCE and MCE are sold through the Siemens Digital Exchange. MCE pricing, bundling with LCE and any runtime licensing for motion are not public. Budget comparisons against TIA Portal therefore need a formal quote. Also ask how the subscription affects long-term maintenance, because a machine may need to be rebuilt and reloaded many years after its original engineering subscription was purchased.

Can I run Simatic AX builds and tests in a CI pipeline?

Yes, the toolchain is designed for it. apax manages packages and runs scripts, apax build compiles software, apax test runs AxUnit tests, and command-line tools compile and load hardware configurations. Siemens’ hardware-engineering example on GitHub shows scripts for compiling, loading, switching CPU modes and comparing online and offline states. What you must design yourself are the gates: registry credentials as secrets, lock-file pinning, a simulation stage for motion changes and a manually approved load to real machines.

Further Reading

By Riju — about

Comments

No comments yet. Why don’t you start the discussion?

Leave a Reply

Your email address will not be published. Required fields are marked *